Lightsources ¥° Lightguides
Measured at 2 a = 50¡Æ; Length 2000 mm; active core¥Õ5mm
Series Standard
Core
Diameters
NA
Applications
and
Spectral Range
Specific Properties
300 2, 3, 5, 8 mm 72¡Æ
UV epoxy curing and UV flourescense inspection at lengths of up to 20 m
(60 ft).
300nm - 650nm.
Superior transmission of up to 5W of UV radiation. Suitable for very rugged environments. Recommended light sources: mercury and xenon short arc, tungsten halogen. Temperature range (long term): -5°C to +35°C
380 2, 3, 5, 8 mm 72¡Æ
Outstanding white light illumination at lenghts of up to 30m (100ft).
340nm - 800nm
Excellent transmission from the near UV to the far red even at a length of 30m. Suitable for very rugged environments. Recommended light sources: tungsten halogen, xenon, metal halide. Temperature range (long term):
-5°C to +35°C
700 5, 8 mm 63¡Æ
White light for medical endoscopy, blue light for dental curing. Lenghts up to 10m (33ft).
400nm - 700nm
Enhanced flexibility, ETO sterilizable. Adaptors available for all medical light sources and endoscopes. Recommended light sources: tungsten halogen, xenon, metal halide. Temperature range
(long term): 0°C to +35°C
2000 2, 3, 5, 8 mm 62¡Æ
Visible and near infrared illumination. Lenghts up to 10m (33ft).
420nm - 2000nm
Transmission of high power near infrared radiation in the multiwatt range. Protection required from high power radiation below 420nm ( integrated longpass filter available). Recommended light sources: xenon or tungsten halogen lamps, Nd-YAG or diode lasers. Temperature range (long term):
+5°C to +35°C
Dimensions of Standard End Fittings (mm)
Active Core ¨ª Standard End Fittings Protective Sleeve Minimum Bending Radius
d0 d1 l1 d2 l2 d3 .
2 4 6.7 8 20 5.5 30
3 5 20 9 24 7 40
5 7 20 10 24 9.5 60
8 10 20 15 40 12.5 100
. . . . . . .
.
Many other end fittings, a variety of claddings, and custom designs are available on request.